Skip to main content

FLIR Systems: safe tank monitoring

Published by , Assistant Editor
Hydrocarbon Engineering,


FLIR Systems has shared how a storage tank inspection company is using an optical gas imaging camera to monitor for fugitive emissions in hazardous locations.

Tank storage companies cannot afford to have chemical leaks due to ageing assets or corroding storage tanks. To allow them to meet increasing safety and environmental regulations and avoid huge fines, Antwerp Distribution and Products Operations (ADPO) relies on third-party inspection agencies, such as The Sniffers, to monitor its facilities for unwanted fugitive emissions. By using the latest GFx320 optical gas imaging camera from FLIR, inspectors from The Sniffers can monitor the ADPO assets up to nine times faster than with traditional toxic vapour analyser (TVA) probes. In addition, because of the remote detection methodology of the FLIR GFx320 optical gas imaging camera they can get to work immediately without going through the hassle of requesting a hot work permit.

The ADPO site in the port of Antwerp, Belgium, has 276 storage tanks of varying sizes, from 150 m3 up to 5000 m3, storing 150 different liquid oil additives, intermediates, commodities and fine chemicals. In hazardous areas like the ADPO plant, there is always the risk of leaking gas vapour collecting and igniting with a stray spark or hot surface. Working in these environments requires specialist equipment, such as the intrinsically safe FLIR GFx320 optical gas imaging camera.

The new application note describes how the GFx320 has eliminated the need to go through all the hassle of requesting a hot work permit which can be a time consuming and expensive process.

Operators have reported how the FLIR GFx320 is easy to carry and much more comfortable to work with than the usual TVA probe gear, especially when on site for an entire day. Using the GFx320 High Sensitivity Mode has allowed the company to detect even smaller leaks very fast. In addition, the GFx320 is capable of measuring temperatures up to 350°C with an accuracy of ±1°C. This is critical for assessing thermal contrast between the gas compound and the background scene. Overall using optical gas and visual images from the GFx320 has been an invaluable tool to clearly demonstrate the severity of a leak thereby enabling ADPO to assess which actions they need to take to fix the leaks and prevent further economic loss.

Read the article online at: https://www.hydrocarbonengineering.com/tanks-terminals/04102017/flir-systems-safe-tank-monitoring/

You might also like

TotalEnergies and SINOPEC join forces to produce SAF

TotalEnergies and China Petroleum and Chemical Corp. (SINOPEC) have signed a Heads of Agreement (HoA) to jointly develop a sustainable aviation fuel (SAF) production unit at a SINOPEC's refinery in China.

 
 

Embed article link: (copy the HTML code below):


 

This article has been tagged under the following:

Downstream news